Marstek Modbus register overview

This reference covers the Marstek Venus register-backed drivers used by Omnibattery. Other battery drivers use their own local API, MQTT, or Home Assistant entity contract and do not use this map.

Writing registers can interrupt normal control

Prefer Omnibattery entities and controls. Raw writes can conflict with automatic control, select an unsafe operating mode, or leave a stale setpoint active. Do not write an address unless you have verified the model, firmware family, data type, scale, and allowed value.

The complete register table is an English-only technical reference.

Firmware families

Code in the complete table Omnibattery hardware selection
a Venus A
d Venus D
e_v12 Venus E v2
e_v3 Venus E v3

A blank cell means that Omnibattery does not define that key for the selected family. It does not prove that the physical address is unused by the firmware.

How to read the table

  • A Modbus register is two bytes. Multi-register values occupy consecutive addresses.
  • Signed and unsigned types must be decoded differently.
  • Apply the listed scale after decoding the raw value.
  • Bit fields represent several independent flags.
  • Calculated rows have no physical register.
Type Typical width Meaning
uint16, int16 one register Unsigned or signed integer
uint32, int32 two registers Unsigned or signed integer
uint48 three registers Unsigned integer
uint64 four registers Unsigned integer or bit field
char variable Text
bit model-specific Flags

Key registers used by control

Purpose Venus E v2 Venus E v3 Venus A Venus D
Battery SOC 32104 37005 32104 32104
Battery power 32102 30001 30001 30001
RS-485 control 42000 42000 42000 42000
Force mode 42010 42010 42010 42010
Charge setpoint 42020 42020 42020 42020
Discharge setpoint 42021 42021 42021 42021
Hardware charging cutoff 44000 Not available Not available Not available
Hardware discharging cutoff 44001 Not available Not available Not available
Maximum charge power 44002 44002 44002 44002
Maximum discharge power 44003 44003 44003 44003

Venus E v3, Venus A, and Venus D state-of-charge cutoffs are enforced in software because those firmware maps do not expose the v2 cutoff registers.

Before diagnosing with raw registers

  1. Confirm the hardware family selected in the config entry.
  2. Compare the related Home Assistant entity with the row in the complete table.
  3. Check whether the row is telemetry, configuration, or an immediate control command.
  4. Download Omnibattery diagnostics before changing anything.
  5. Use the troubleshooting guide and battery entities first.
Transport timing

Omnibattery applies firmware-specific pacing and timeouts itself. Venus E v3, Venus A, and Venus D require a minimum of 150 ms between Modbus TCP messages; Venus E v2 requires 50 ms. External polling or writes on the same connection can delay replies and interfere with controller traffic. An RS-485 gateway uses a separate, shorter pacing profile from the battery's native Modbus TCP server.