Home Assistant entities
The integration automatically creates entities for each configured battery and aggregated sensors for the whole system.
Sensors (per battery)
| Entity |
Description |
Unit |
sensor.*_battery_soc |
State of charge |
% |
sensor.*_battery_power |
Current power |
W |
sensor.*_battery_voltage |
Voltage |
V |
sensor.*_battery_current |
Current |
A |
sensor.*_battery_temperature |
Temperature |
°C |
sensor.*_total_charging_energy |
Total charging energy |
kWh |
sensor.*_total_discharging_energy |
Total discharging energy |
kWh |
sensor.*_battery_cycle_count |
Cycle count (register, v3/vA/vD) |
— |
sensor.*_battery_cycle_count_calc |
Calculated cycle count (all versions) |
— |
sensor.*_max_cell_voltage |
Max cell voltage (v3/vA/vD) |
V |
sensor.*_min_cell_voltage |
Min cell voltage (v3/vA/vD) |
V |
sensor.*_alarm_status |
Active alarm conditions (v2) — diagnostic |
text |
sensor.*_fault_status |
Active fault conditions (v2) — diagnostic |
text |
| Entity |
Description |
sensor.*_device_name |
Device name |
sensor.*_sn_code |
Serial number |
sensor.*_software_version |
Firmware version |
sensor.*_bms_version |
BMS version |
sensor.*_mac_address |
MAC address |
Binary sensors
| Entity |
Description |
binary_sensor.*_wifi_status |
WiFi status |
binary_sensor.*_cloud_status |
Cloud status |
binary_sensor.marstek_venus_system_predictive_charging_active |
Predictive charging active (system) |
Numbers (sliders)
| Entity |
Description |
Range |
number.*_max_soc |
Maximum SOC |
0–100 % |
number.*_min_soc |
Minimum SOC |
0–100 % |
number.*_max_charge_power |
Max charge power |
W |
number.*_max_discharge_power |
Max discharge power |
W |
Selects
| Entity |
Options |
select.*_force_mode |
None / Charge / Discharge |
Switches
| Entity |
Description |
switch.*_rs485_control |
RS485 control mode |
switch.*_backup_function |
Backup function — when enabled and AC offgrid power ≠ 0 W, the battery is excluded from PD control (no write commands sent) |
switch.marstek_venus_system_override_predictive_charging |
Override predictive charging |
| Entity |
Description |
button.*_reset |
Device reset |
System aggregate sensors
Available under the sensor.marstek_venus_system_* prefix, summing values across all batteries:
system_battery_power — Total system power
system_battery_soc — System average SOC
system_total_charging_energy — Total system charging energy
system_total_discharging_energy — Total system discharging energy
grid_at_min_soc — Grid import during min SOC periods (kWh)
system_alarm_status — Aggregated alarm state across all batteries (OK / Warning / Fault); attributes list active conditions per battery